Version 2.0
16.06.2000
VI TELEFILTER
Measurement condition
Ambient temperature: Input power level: terminating impedances input: output: 20 ... 25 52
Filter specification
TFS 199 C
1/5
C dBm
1,1 k || -6.0 pF single ended 1,2 k || -6.2 pF single ended
Characteristics
Remark: Reference level for the relative attenuation arel of the TFS 199 C is the minimum of the pass band attenuation amin. The minimum of the pass band attenuation amin is defined as the insertion loss ae. The centre frequency fc is the arithmetic mean value of the upper and lower frequencies at the 1 dB filter attenuation level relative to the insertion loss ae. The given values for the relative attenuation arel and for the group delay ripple have to be reached at the frequencies given below also if the centre frequency fo is shifted due to the temperature coefficient of frequency TCf in the operating temperature range and due to a production tolerance for the centre frequency fo.
Data
Insertion loss Nominal frequency Relative attenuation fN - 100 kHz ... fN + fN fN fN fN fN 80 30 600 + 800 + 17
ae = amin fN arel
typ. value
limit
max. 8,0 dB 199,0 MHz
-
100
kHz MHz kHz kHz MHz MHz
max. min. min. min. min. min.
0,5 dB 30 25 20 25 35 dB dB dB dB dB
MHz ... fN 30 MHz ... fN - 800 kHz ... fN 800 kHz ... fN + 17 kHz ... fN + 80
Group delay ripple GD fC - 100 kHz ... fC + 100 kHz Input power level short test standard operation Permissible DC voltage Operating temperature range Storage temperature range Temperature coefficient
TC
-
max. 500
ns
max. + 18 max. + 10 max. 10
dBm dBm V
-35 C ... + 85 C -35 C ... + 85 C - 0,036 ppm/K
23 C Frequency inversion temperature To ______________________________________________________________________________________________________
Generated: Checked / approved:
______________________________________________________________________________________________________ VI TELEFILTER Vectron International, Inc. Potsdamer Strae 18 267 Lowell Road D 14 513 TELTOW / Germany Hudson, NH 03051 / USA Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 Tel: (603) 598-0070 Fax: (603) 598-0075 E-Mail: tft@telefilter.com E-Mail: vti@vtinh.com ______________________________________________________________________________________________________ VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
TFS199C.doc
Version 2.0
16.06.2000
VI TELEFILTER
Filter specification
TFS 199 C
2/5
Construction and pin connection
(All dimensions in mm)
15,37 0,20
TFS199C L9
1
120
1,0 0,2
6,50 0,20
2,0Max.
1 2 3 4 5 6 7 8 9 10
Input Ground Ground Ground Output Output Ground Ground Ground Input
1,9 0,2 1,91 7,62 0,2 0,2
50 test circuit
L1 10 Input 50 Ohm L3 6 L2 1 L5 5 Output L4
SAW
L6 50 Ohm
2,3,4,7,8,9
______________________________________________________________________________________________________ VI TELEFILTER Vectron International, Inc. Potsdamer Strae 18 267 Lowell Road D 14 513 TELTOW / Germany Hudson, NH 03051 / USA Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 Tel: (603) 598-0070 Fax: (603) 598-0075 E-Mail: tft@telefilter.com E-Mail: vti@vtinh.com ______________________________________________________________________________________________________ VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
TFS199C.doc
Version 2.0
16.06.2000
VI TELEFILTER
Stability characteristics
Filter specification
TFS 199 C
3/5
After the following tests the filter shall meet the whole specification: 1. Shock: 2. Vibration: 3. Damp heat: (cycle) 4. Resistance to solder heat (reflow): 500g, 18 ms, half sine wave, 3 shocks each plane; DIN IEC 68 T2 - 27 10 Hz to 500 Hz, 0,35 mm or 5g respectively, 1 octave per min, 10 cycles per plan, 3 plans; DIN IEC 68 T2 - 6 25 C to 55C / 95% r.H. / 10 cycles DIN IEC 68 - 2 - 30 Db max. 2 times reflow process; for temperature conditions refer to the attached "Air reflow temperature conditions" on page 4;
Packing
Tape & Reel: IEC 286 - 3, with exception of value for N and minimum bending radius; tape type II, embossed carrier tape with top cover tape on the upper side; max. pieces of filters per reel: Reel of empty components at start: Reel of empty components at start including leader: Trailer
Tape (all dimensions in mm) W Po Do E : : : : 24 0,3 4 0,1 1,5 + 0,1 1,75 0,1 11,5 0,1 0,60 2 12 1,5 7,1 13,9 21,5 0,1 0,1 0,2 0,2 0,1
P1 Ct Bo
2000 min 300 mm min 500 mm min 300 mm
EMBOSSED CARRIER TAPE
Do
Po
P2
E Ao F W
F : G (min) : P2 : P1 : D1(min) : Ao : Bo Ct : :
D1
G
COVER TAPE
W2
Reel (all dimensions in mm): A W1 W2 (max) : N (min) C : : : : 330 24,40 +2,0 30,4 >= 60
C A
13
0,5/-0.2
N
W1
The minimum bending radius is 45 mm. The mounting surface of the filters faces the bottom side of the embossed carrier tape. The marking of the filters is able to read if the view is directed on the upper side of the carrier tape with the sprocket holes on the right side of the tape.
______________________________________________________________________________________________________ VI TELEFILTER Vectron International, Inc. Potsdamer Strae 18 267 Lowell Road D 14 513 TELTOW / Germany Hudson, NH 03051 / USA Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 Tel: (603) 598-0070 Fax: (603) 598-0075 E-Mail: tft@telefilter.com E-Mail: vti@vtinh.com ______________________________________________________________________________________________________ VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
TFS199C.doc
Version 2.0
16.06.2000
VI TELEFILTER
Air reflow temperature conditions
Filter specification
TFS 199 C
4/5
1st and 2nd air reflow profile Name: Temperature: Time: pre-heating periods 150 C - 170 C 60 sec. - 90 sec. main-heating periods over 200 C 20 sec. - 25 sec. peak temperature 255 C 5 C
Chip-mount air reflow profile
260 240 220 200 180 temperature / C 160 140 120 100 80 60 40 20 0 0 20 40 60 80 100 120 time / sec. 140 160 180 200 220 240
Table for temperature vs. time during the air reflow process Tolerance of temperatures: 5 C time / sec. 0 10 20 30 40 50 60 70 80 90 100 110 120 130 temperature / C 23 34 46 60 80 103 121 134 143 150 154 156 158 159 time / sec. 140 150 160 170 180 190 195 200 205 210 215 220 230 240 temperature / C 160 161 164 170 180 205 230 255 230 205 180 165 140 120
______________________________________________________________________________________________________ VI TELEFILTER Vectron International, Inc. Potsdamer Strae 18 267 Lowell Road D 14 513 TELTOW / Germany Hudson, NH 03051 / USA Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 Tel: (603) 598-0070 Fax: (603) 598-0075 E-Mail: tft@telefilter.com E-Mail: vti@vtinh.com ______________________________________________________________________________________________________ VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
TFS199C.doc
Version 2.0
16.06.2000
VI TELEFILTER
History
Version 1.0 2.0 Reason of Changes
Filter specification
TFS 199 C
5/5
Name Steiner Steiner
Date 05.11.1999 16.06.2000
-generation of specification - extend specification to a filter specification
______________________________________________________________________________________________________ VI TELEFILTER Vectron International, Inc. Potsdamer Strae 18 267 Lowell Road D 14 513 TELTOW / Germany Hudson, NH 03051 / USA Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 Tel: (603) 598-0070 Fax: (603) 598-0075 E-Mail: tft@telefilter.com E-Mail: vti@vtinh.com ______________________________________________________________________________________________________ VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.


▲Up To Search▲   

 
Price & Availability of TFS199C

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X